APPENDIX 4 ALERT LIST
AP-27
10001 6 015 Sub Monitor Fan2
Rotation Speed
Lowering
Caution/B For MU-231: Con-
nected to COM2
(Sub Monitor).
Fan2 rotation speed
is below threshold.
If the error fre-
quently
occurs, contact
FURUNO and in-
form frequency of
occurrence.
10001 7 016 Sub Monitor Fan3
Rotation Speed
Lowering
For MU-231: Con-
nected to COM2
(Sub Monitor).
Fan3 rotation speed
is below threshold.
If the error fre-
quently
occurs, contact
FURUNO and in-
form frequency of
occurrence.
10001 8 017 Sub Monitor Fan4
Rotation Speed
Lowering
For MU-190: Con-
nected to COM2
(Sub Monitor).
Fan4 rotation speed
is below threshold.
If the error fre-
quently
occurs, contact
FURUNO and in-
form frequency of
occurrence.
10001 9 011 Main Monitor
RS485 Communi-
cation Timeout
For MU-190/231:
Connected to
COM1. There has
been no communi-
cation from proces-
sor unit through
RS485 for 180 sec-
onds. (No commu-
nication implies in
completed sen-
tence or checksum
error.)
Check the connec-
tion of brightness
control cable.
10001 10 024 Sub Monitor
RS485 Communi-
cation Timeout
For MU-190/231:
Connected to
COM2. There has
been no communi-
cation from proces-
sor unit through
RS485 for 180 sec-
onds. (No commu-
nication implies
incomplete sen-
tence or checksum
error.)
Check the connec-
tion of brightness
control cable.
10001 11 012 Main Monitor No
Signal
For MU-190/231:
Connected to
COM1. There has
been no signal con-
tinuously for 60 sec-
onds.
Check the connec-
tion of video cable.
10001 12 025 Sub Monitor No
Signal
For MU-190/231:
Connected to
COM2. There has
been no signal con-
tinuously for 60 sec-
onds.
Check the connec-
tion of video cable.
ALF ALR
Alert name
Priority/
Category
Meaning Remedy