APPENDIX 4 ALERT LIST
AP-32
10002 17 086 Processor Unit
CPU board 5V
Power Error
Warning/
B
5 V power voltage
of CPU board in
processor unit is out
of threshold.
If the error fre-
quently occurs,
contact FURUNO
and inform fre-
quency of
occurrence.
10002 18 087 Processor Unit
CPU board 3.3V
Power Error
3.3 V power voltage
of CPU board in
processor unit is out
of threshold.
If the error fre-
quently occurs,
contact FURUNO
and inform fre-
quency of
occurrence.
10002 19 088 Processor Unit
CPU board 12V
Power Error
12 V power voltage
of CPU board in
processor unit is out
of threshold.
If the error fre-
quently occurs,
contact FURUNO
and inform fre-
quency of
occurrence.
10050 1 320 Processor Unit
Ch.01 COM Time-
out
Caution/B Input from EC-3000
serial ch.1 has been
discontinued for
more than certain
time.
(Set at installation)
Default: No timeout
Check the connec-
tion of Ch.1.
10050 2 321 Processor Unit
Ch.02 COM Time-
out
Input from EC-3000
serial ch.2 has been
discontinued for
more than certain
time.
(Set at installation)
Default: No timeout
Check the connec-
tion of Ch.2.
10050 3 322 Processor Unit
Ch.03 COM Time-
out
Input from EC-3000
serial ch.3 has been
discontinued for
more than certain
time.
(Set at installation)
Default: No timeout
Check the connec-
tion of Ch.3.
10050 4 323 Processor Unit
Ch.04 COM Time-
out
Input from EC-3000
serial ch.4 has been
discontinued for
more than certain
time.
(Set at installation)
Default: No timeout
Check the connec-
tion of Ch.4.
10050 5 324 Processor Unit
Ch.05 COM Time-
out
Input from EC-3000
serial ch.5 has been
discontinued for
more than certain
time.
(Set at installation)
Default: No timeout
Check the connec-
tion of Ch.5.
ALF ALR
Alert name
Priority/
Category
Meaning Remedy
No. Inst.* No.