EasyManua.ls Logo

Hioki PQ3100 - Harmonic Calculation Formulas (Voltage, Current, Power)

Hioki PQ3100
242 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
187
Calculation Formula
CH 1 to 4 sum/AVG Comment
Pharm (Content
percentage)
{(N-th order harmonic average value)
/ (Fundamental average value)} ×
100%
Uphase Vector average
Iphase Vector average
Pphase Vector average
Uthd-F/Uthd-R Calculated from mean squared RMS
values
Ithd-F/Ithd-R Calculated from mean squared RMS
values
KF Calculated from mean squared RMS
values
Signed averaging: Signs of values are included in average calculation.
AVG calculation of Uphase
cki
ckr
U
U
1
tan
Here,
U
ckr
and
U
cki
use the signed average values for each channel.
AVG calculation of Iphase
cki
ckr
I
I
1
tan
Here,
I
ckr
and
I
cki
use the signed average values for each channel.
AVG calculation of Pphase
(Averaging process for each channel)
k
k
Pharm
Qharm
1
tan
Here,
Qharm
k
and
Pharm
k
use the signed average values for each channel.
(Averaging process of the sum)
sumk
sumk
P
Q
1
tan
Here,
Q
sumk
and
P
sumk
use the sum calculation of the signed average results for each channel.
14
Specications

Table of Contents

Other manuals for Hioki PQ3100

Related product manuals