HP P2000 G3 MSA System CLI Reference Guide 315
cache string Shows whether cache debug messages are enabled for inclusion in the Storage
Controller debug log.
Off: Disabled.
On: Enabled. This is the default.
cache-numeric string Numeric equivalents for cache values.
0: Off
1: On
emp string Shows whether EMP debug messages are enabled for inclusion in the Storage
Controller debug log.
Off: Disabled.
On: Enabled. This is the default.
emp-numeric string Numeric equivalents for emp values.
0: Off
1: On
capi string Shows whether Internal Configuration API debug messages are enabled for
inclusion in the Storage Controller debug log.
Off: Disabled.
On: Enabled. This is the default.
capi-numeric string Numeric equivalents for capi values.
0: Off
1: On
mui string Shows whether internal service interface debug messages are enabled for
inclusion in the Storage Controller debug log.
Off: Disabled.
On: Enabled. This is the default.
mui-numeric string Numeric equivalents for mui values.
0: Off
1: On
bkcfg string Shows whether internal configuration debug messages are enabled for inclusion
in the Storage Controller debug log.
Off: Disabled.
On: Enabled. This is the default.
bkcfg-numeric string Numeric equivalents for bkcfg values.
0: Off
1: On
awt string Shows whether debug messages for auto-write-through cache triggers are
enabled for inclusion in the Storage Controller debug log.
Off: Disabled. This is the default.
On: Enabled.
awt-numeric string Numeric equivalents for awt values.
0: Off
1: On
Table 20 debug-log-parameters properties (continued)