HP P2000 G3 MSA System CLI Reference Guide 421
num-drives-per-
low-level-array
uint8 • For a RAID-10 or RAID-50 vdisk, the number of disks in each sub-vdisk.
• For other RAID levels, 1.
num-expansion-
partitions
uint8 Not used.
num-partition-
segments
uint8 Number of free segments available for expansion of volumes.
new-partition-
lba
string Maximum number of 512-byte blocks that could be allocated to a newly created
volume. The value is formatted to use the current base, precision, and units.
Expanding a volume in the same vdisk will reduce this amount.
new-partition-
lba-numeric
string Unformatted new-partition-lba value in 512-byte blocks.
array-drive-
type
string Type of disk used in the vdisk.
• SAS: Dual-port SAS.
• SAS-S: Single-port SAS.
• SATA: Dual-port SATA.
• SATA-S: Single-port SATA.
array-drive-
type-numeric
string Numeric equivalents for array-drive-type values.
• 3: SATA
• 4: SAS
• 5: SATA-S
• 6: SAS-S
is-job-auto-
abortable
string • false: The current job must be manually aborted before you can delete the
vdisk.
• true: The current job will automatically abort if you delete the vdisk.
is-job-auto-
abortable-
numeric
string • 0: false
• 1: true
serial-number string Vdisk serial number.
blocks uint64 Unformatted size value in 512-byte blocks.
health string • OK
• Degraded
• Fault
• Unknown
• N/A
health-numeric string Numeric equivalents for health values.
• 0: OK
• 1: Degraded
• 2: Fault
• 3: Unknown
• 4: N/A
health-reason string More information about the health value.
Table 83 virtual-disks properties (continued)
Name Type Description