239
Syntax
mrp timer join timer-value
undo mrp timer join
Default
The Join timer is 20 centiseconds.
Views
Layer 2 Ethernet interface view
Layer 2 aggregate interface view
Predefined user roles
network-admin
Parameters
timer-value: Specifies the Join timer value (in centiseconds). The Join timer must meet the
following requirements:
• Not less than 20 centiseconds.
• Less than half the Leave timer.
• Divisible by 20 centiseconds.
Examples
# Set the Join timer to 40 centiseconds. (In this example, the Leave timer is 100 centiseconds.)
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] mrp timer join 40
Related commands
display mvrp running-status
mrp timer leave
mrp timer leave
Use mrp timer leave to set the Leave timer.
Use
undo mrp timer leave to restore the default.
Syntax
mrp timer leave timer-value
undo mrp timer leave
Default
The Leave timer is 60 centiseconds.
Views
Layer 2 Ethernet interface view
Layer 2 aggregate interface view
Predefined user roles
network-admin

Table of Contents

Other manuals for HPE FlexNetwork 5130 EI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork 5130 EI Series and is the answer not in the manual?

HPE FlexNetwork 5130 EI Series Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork 5130 EI Series
CategorySwitch
LanguageEnglish

Related product manuals