22
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-gigabitethernet 1/0/1] flow-control receive enable
Related commands
flow-control
flow-interval
Use flow-interval to set the statistics polling interval.
Use
undo flow-interval to restore the default.
Syntax
flow-interval interval
undo flow-interval
Default
The statistics polling interval is 300 seconds.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
interval: Sets the statistics polling interval in seconds. The interval is in the range of 5 to 300 and
must be a multiple of 5.
Examples
# Set the statistics polling interval to 100 seconds on GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] flow-interval 100
interface
Use interface to enter interface view.
Syntax
interface interface-type interface-number
Views
System view
Predefined user roles
network-admin
Parameters
interface-type: Specifies an interface type.
interface-number: Specifies an interface number.