28
If you do not specify an interface type, this command clears statistics for all interfaces.
If you specify an interface type but do not specify an interface number, this command clears statistics
for all interfaces of the specified type.
Examples
# Clear the statistics for GigabitEthernet 1/0/1.
<Sysname> reset counters interface gigabitethernet 1/0/1
Related commands
display counters interface
display counters rate interface
display interface
reset ethernet statistics
Use reset ethernet statistics to clear the Ethernet module statistics.
Syntax
reset ethernet statistics [ slot slot-number ]
Views
User view
Predefined user roles
network-admin
Parameters
slot slot-number: Specifies an IRF member device by its member ID. If you do not specify a
member device, this command clears statistics for all IRF member devices.
Examples
# Clear the Ethernet module statistics for the specified slot.
<Sysname> reset ethernet statistics slot 1
Related commands
display ethernet statistics
reset packet-drop interface
Use reset packet-drop interface to clear the dropped packet statistics for an interface.
Syntax
reset packet-drop interface [ interface-type [ interface-number ] ]
Views
User view
Predefined user roles
network-admin
Parameters
interface-type: Specify an interface type.
interface-number: Specify an interface number.