289
Examples
# Set the interval for fast LLDP frame transmission to 2 seconds.
<Sysname> system-view
[Sysname] lldp timer fast-interval 2
lldp timer notification-interval
Use lldp timer notification-interval to set the LLDP trap and LLDP-MED trap
transmission interval.
Use undo lldp timer notification-interval to restore the default.
Syntax
lldp timer notification-interval interval
undo lldp timer notification-interval
Default
The LLDP trap and LLDP-MED trap transmission interval is 30 seconds.
Views
System view
Predefined user roles
network-admin
Parameters
interval: Sets the LLDP trap and LLDP-MED trap transmission interval in the range of 5 to 3600
seconds.
Examples
# Set both the LLDP trap and LLDP-MED trap transmission interval to 8 seconds.
<Sysname> system-view
[Sysname] lldp timer notification-interval 8
lldp timer reinit-delay
Use lldp timer reinit-delay to set the LLDP reinitialization delay.
Use
undo lldp timer reinit-delay to restore the default.
Syntax
lldp timer reinit-delay delay
undo lldp timer reinit-delay
Default
The LLDP reinitialization delay is 2 seconds.
Views
System view
Predefined user roles
network-admin

Table of Contents

Other manuals for HPE FlexNetwork 5130 EI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork 5130 EI Series and is the answer not in the manual?

HPE FlexNetwork 5130 EI Series Specifications

General IconGeneral
BrandHPE
ModelFlexNetwork 5130 EI Series
CategorySwitch
LanguageEnglish

Related product manuals