No. Data
1 Manager and name of the NQA test instance
2 Destination MAC address of the NQA test instance
3 Maintenance domain (MD) and maintenance association (MA) of the NQA test
instance
4 Starting and ending modes of the NQA test instance
6.15.2 Setting Parameters for the MAC Ping Test
Context
Do as follows on the NQA client.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
cfm enable
The CFM is enabled globally.
Step 3 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 4 Run:
test-type macping
The test type is set to MAC Ping.
Step 5 Run:
destination-address mac mac-address
The destination MAC address of the MAC ping test is configured.
Step 6 Run:
md md-name ma ma-name
The MD and the MA are specified.
Step 7 (Optional) Run the following commands to set other parameters for the MAC Ping test.
l Run:
interval seconds interval
The interval for sending test packets is set.
l Run:
fail-percent percent
Quidway S9300 Terabit Routing Switch
Configuration Guide - Network Management 6 NQA Configuration
Issue 03 (2010-09-20) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6-43