The NQA test is started.
Select the start mode as required because the start command has several forms.
l To perform the NQA test immediately, run the start now [ end { at [ yyyy/mm/dd ]
hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime { seconds second | hh:mm:ss } ]
command.
The test instance is started immediately.
l To perform the NQA test at the specified time, run the start at [ yyyy/mm/dd ] hh:mm:ss
[ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime
{ seconds second | hh:mm:ss } ] command.
The test instance is started at a specified time.
l To perform the NQA test after a certain delay period, run the start delay { seconds second
| hh:mm:ss } [ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } |
lifetime { seconds second | hh:mm:ss } ] command.
The test instance is started after a certain delay.
----End
6.18.3 Configuring LSP Traceroute Test Parameters for the MPLS
TE Tunnel
This part describes how to set parameters for a TE LSP traceroute test.
Context
Do as follows on the NQA client:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
test-type lsptrace
The test type is set to LSP Traceroute.
Step 4 Run:
lsp-type te
The tunnel type is set to be the MPLS TE tunnel.
Step 5 Run:
lsp-tetunnel tunnel tunnel-number
The TE tunnel interface to be tested is configured.