Commonly, the default configurations of the universal parameters are adopted.
Pre-configuration Tasks
Before configuring universal NQA parameters, create NQA tests correctly.
6.30.2 Configuring Universal Parameters for the NQA Test Instance
This part describes the application of each parameter in the NQA test instance.
Context
Do as follows on the NQA client:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
The NQA test instance view is displayed.
Step 3 Perform the following as required to configure universal parameters:
l Run:
agetime hh:mm:ss
The aging time is set for the NQA test instance.
l Run:
alarm entry-number { lost-packet-ratio | jitter-average | jitter-ds-average |
jitter-sd-average | packet-loss-ds | packet-loss-sd | rtt-average } { absolute
| delta } { falling-threshold threshold-value1 event-entry1 | rising-threshold
threshold-value2 event-entry2 } * [ description ]
Configuration NQA alarms for the NQA test instance.
NOTE
This parameter cannot be configured for Mtrace test instances.
l Run:
datafill fillstring
The fill string is set for the NQA test instance.
NOTE
This parameter cannot be configured for SNMP, TCP, FTP, HTTP, LSPTrace, DNS, PWE3 Trace, and
MTrace test instances. In the case that the icmp-jitter-type of the ICMPJitter or PathJitter test instanceis
is icmp-echo, This parameter can be configured for ICMPJitter and PathJitter.
l Run:
datasize size
The packet size is set for the NQA test instance.
NOTE
This parameter cannot be configured for SNMP, TCP, FTP, ICMP Jitter, Path Jitter, LSP Trace, HTTP,
DNS, PWE3 Trace, and MTrace test instances.
Quidway S9300 Terabit Routing Switch
Configuration Guide - Network Management 6 NQA Configuration
Issue 03 (2010-09-20) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6-113