MANUAL ADDENDUM
RADAR VERSION 3.
5
3
If the FILL SILENCE preference is set to ASK, a FILL SILENCE option will have to be chosen
for each export or BWAV backup.
To set the FILL SILENCE preference:
a. Use the , the and keys and the key to go to the MAIN MENU / FILE
MENU / FILE PREFS / FILL SILENCE selection and press the key.
b.
At the FILL SILENCE prompt, use the and keys to select:
ASK Will prompt for fill silence option each export/BWAV backup
FILL GAPS ONLY FILL ALL GAPS without FRONT FILL or BACK FILL
FRONT FILL+GAPS FRONT FILL and FILL GAPS without BACK FILL
GAPS+BACK FILL BACK FILL and FILL GAPS without FRONT FILL
FRONT+GAPS+BACK FRONT FILL and BACK FILL and FILL GAPS
FRONT FILL ONLY FRONT FILL without FILL GAPS or BACK FILL
NO Each Export/BWAV backup will transfer without fill options
Make a selection and press the key. The factory default setting is ASK.
If the FILL SILENCE preference in the FILE PREFS menu is set to ALL in a previous
version of software, it will be converted to FRONT+GAPS+BACK when version 3.52+ is
installed. This is the setting to use to import back into RADAR and paste to ORIG TIME
because it guarantees that all exported tracks will be aligned.