-221, "Settings conflict; cannot have immediate, no-holdoff gate stop for frequency or totalize meas-
urements; GATE:STOP:HOLD:SOUR TIME set"
-221, "Settings conflict; cannot use READ? with continuous totalize"
-221, "Settings conflict; external gating not compatible with gate output; gate output disabled"
-221, "Settings conflict; histogram bin width is 0.0; CALC2:TRAN:HIST:RANG:AUTO ON set"
-221, "Settings conflict; histogram lower range > upper range; CALC2:TRAN:HIST:RANG:AUTO ON set"
-221, "Settings conflict; infinite stop holdoff time for frequency; SENS:FREQ:GATE:SOUR set to TIME"
-221, "Settings conflict; infinite stop holdoff time for time interval; SENS:TINT:GATE:SOUR set to IMM"
-221, "Settings conflict; input range not compatible with input probe factor; INP:RANG set to 50V range"
-221, "Settings conflict; input threshold voltage > input range; threshold clipped to range"
-221, "Settings conflict; low reference >= high reference"
-221, "Settings conflict; low reference >= high reference; reference values changed to defaults"
-221, "Settings conflict; lower limit > upper limit; CALC:LIM:UPP set to CALC:LIM:LOW value"
-221, "Settings conflict; lower reference and upper reference have different units"
-221, "Settings conflict; stop holdoff < minimum gate time for frequency or totalize;
SENSe:GATE:STOP:HOLD:TIME set to minimum"
-221, "Settings conflict; trigger source is BUS"
-222, "Data out of range"
-222, "Data out of range; value clipped to lower limit"
-222, "Data out of range; value clipped to upper limit"
-223, "Too much data"
-224, "Illegal parameter value"
-225, "Out of memory; measurement data overrun"
-230, "Data corrupt or stale"
-240, "Hardware error; CPU board initialization failed"
-240, "Hardware error; GPIB interface failed
-240, "Hardware error; cannot communicate with channel 3 hardware"
-240, "Hardware error; cannot communicate with measurement hardware"
-240, "Hardware error; channel 3 operation failed"
-240, "Hardware error; measurement hardware initialization failed"
-240, "Hardware error; measurement operation failed"
-240, "Hardware error; failed to program measurement FPGA security EEProm"
-241, "Hardware missing"
Keysight 53220A/53230A Programmer's Reference 473
SCPI Error Messages