Keysight 53220A/230A Command Quick Reference
Printable PDF Version
Syntax Conventions
l Braces ( { } ) enclose the parameter choices for a given command string. The braces are not sent with the command string.
l A vertical bar ( | ) separates multiple parameter choices for a given command string. The bar is not sent with the command
string.
l Triangle brackets ( < > ) indicate that you must specify a value for the enclosed parameter. For example, the above syntax
statement shows the <range> parameter enclosed in triangle brackets. The brackets are not sent with the command string.
You must specify a value for the parameter (e.g., "TRIG:COUN 10").
l Some parameters are enclosed in square brackets ( [ ] ). The square brackets indicate that the parameter is optional and
can be omitted. The brackets are not sent with the command string. If you do not specify a value for an optional parameter,
the instrument chooses a default value.
Measurement Commands
MEASure:ARRay:TSTamp? [(<count>)[,<channel>]]
MEASure:FREQuency? [{<expected> | MINimum | MAXimum | DEFault} [,{<resolution> | MINimum | MAXimum |
DEFault}]] [,<channel>]
MEASure:FREQuency:BURSt? [<channel>]
MEASure:FREQuency:PRF? [{<expected> | MINimum | MAXimum | DEFault} [,{<resolution> | MINimum | MAXimum |
DEFault}]] [,<channel>]
MEASure:FREQuency:PRI? [{<expected> | MINimum | MAXimum | DEFault} [,{<resolution> | MINimum | MAXimum |
DEFault}]] [,<channel>]
MEASure:FREQuency:RATio? [{<expected> | MINimum | MAXimum | DEFault} [,{<resolution> | MINimum | MAXimum |
DEFault}]] [,<channel_pair>]
MEASure:PERiod? [{<expected> | MINimum | MAXimum | DEFault} [,{<resolution> | MINimum | MAXimum | DEFault}]]
[,<channel>]
MEASure:SPERiod? [<channel>]
MEASure:TINTerval? [<channel_pair>]
MEASure:FTIMe? [{<lower_reference> | MINimum | MAXimum | DEFault} [,{<upper_reference> | MINimum | MAXimum |
DEFault}]] [,<channel>]
MEASure:RTIMe? [{<lower_reference> | MINimum | MAXimum | DEFault} [,{<upper_reference> | MINimum | MAXimum |
DEFault}]] [,<channel>]
MEASure:NDUTycycle? [{<reference> | MINimum | MAXimum | DEFault}] [,<channel>]
MEASure:PDUTycycle? [{<reference> | MINimum | MAXimum | DEFault}] [,<channel>]
MEASure:NWIDth? [{<reference> | MINimum | MAXimum | DEFault}] [,<channel>]
MEASure:NWIDth:BURSt? [<channel>]
MEASure:PWIDth? [{<reference> | MINimum | MAXimum | DEFault}] [,<channel>]
MEASure:PWIDth:BURSt? [<channel>]
MEASure:PHASe? [<channel_pair>]
Keysight 53220A/53230A Programmer's Reference 479