Terminal – Machine Functions [Medium/Comfort Version Electronics]
176
Pos: 103.66.1 /Ü berschriften/Ü berschriften 2/P-T /SSoll-Press klappendruck einstellen (Ha ndbetrieb) @ 352 \mod_1437545 367243_78.doc x @ 26371 11 @ 2 @ 1
14.22 Setting the target bale channel flap pressure (manual mode)
Pos: 103.66.2 / BA/Info-Center /Großpackenpre sse/Grundbild H andbetrieb/ Warnung zu hoh er Druck @ 18\mod_ 1237389601150_ 78.docx @ 210 149 @ @ 1
WARNING! – Pressure too high!
Effect: Damage to the machine
• If the pressure is set too high, the machine could be subjected to a mechanical overload
during baling that could result in destroying it To avoid this, the bale channel flap pressure
should be reduced to a non-critical value just before the overload. After a few seconds, it is
possible to return to the pressure set by the user.
• If overload occurs the target bale channel flap pressure must be reduced
Pos: 103.66.3 / BA/Info-Center /CCI-ISOBUS-T erminal/CCI-Bi G Pack/Grund bild Handbetrie b/Einstellen des Soll-Pressklap pendrucks Bild H S Baureihe @ 352\mod_14 37469449273 _78.docx @ 263 5981 @ @ 1
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11F11
F12
1/2
Fig.
Pos: 103.66.4 / BA/Info-Center /Großpackenpre sse/Grundbild H andbetrieb/Soll- Pressklappe ndrucks einstelle n: Einführung @ 352\mod_ 1437546034532_ 78.docx @ 2 637142 @ @ 1
The pressure is specified by the user in manual mode. The pressure is built up immediately if
the PTO shaft is running and the machine is stopped. The pressure display barely fluctuates in
the display. To avoid damaging the machine, the bale channel flap pressure is reduced by the
system to a non-critical value just before an overload. After several seconds, the pressure set
by the user is built up again. The bale channel flap pressure is displayed in bar or PSI
depending on the selected unit of measurement Metric or US.
Value (1) and the bar display = actual bale channel flap pressure
Value (2) and the marks in the bar display = set target bale channel flap pressure
Pos: 103.66.5 / BA/Info-Center /Großpackenpre sse/Grundbild H andbetrieb/Soll- Pressklappe ndrucks einstelle n @ 381\mo d_144404638 7414_78.docx @ 2 749823 @ @ 1
Setting the target bale channel flap pressure
Manual mode has been selected.
• Change the value, see chapter Terminal – Menus, "Changing the value".
Pos: 103.66.6 / Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196 175311226_0. docx @ 4165 @ @ 1