Pos: 103.313 /BA/I nfo-Center/ Großpackenpress e/Hauptmenüs/ Alarmmeldunge n/1) Alarm meldungen Tabell e allgemein A1 5(515) - A18( 518) HS Baurei he @ 386\ mod_1444922756 729_78.doc x @ 2770341 @ @ 1
No./symbol
Possible cause
Remedy
A15/515
High
Overvoltage
Tractor alternator is defective.
Check the tractor alternator.
A17/517
The CAN connection between
the job computer and the
KRONE measurement force
computer (KMV2) is
interrupted.
The CAN wiring is defective.
The KRONE moisture
measurement computer is
inactive.
Check the CAN wiring.
Replace the KRONE moisture
measurement computer (RMC).
A18/518
The CAN connection between
the job computer and the
KRONE PIC-I01 computer is
interrupted.
Check the CAN wiring.
Replace the KRONE PIC-I01
computer.