Terminal – Menus [Medium/Comfort Version Electronics]
240
Pos: 103.318 /BA/I nfo-Center/ Großpackenpress e/Hauptmenü s/Alarmmeldung en/3) Alar mmeldungen Ta belle allgemein 10-37 HS Baur eihe @ 375\m od_14425663330 47_78.docx @ 2724112 @ @ 1
– Error on the pressure limiting
valve
– The pressure sensor is defective.
• Switch off the PTO shaft.
• Check the pressure limiting valve
for blockage.
• Replace the pressure sensor.
– The PTO shaft is rotating when
entering sensor or actuator
diagnostics or during diagnostics.
• Switch off the PTO shaft
immediately.
• Perform diagnostics when the
PTO shaft is at a standstill.
– The blade bar is down during
baling.
– The shear screw is torn.
• Replace the shear screw.
• Check the needles.
• Check the swivel range of the
needles.
• Check the twine guide.
– The shear screw is torn.
– The total force of pressure on the
machine has been exceeded.
In manual mode:
• Reduce the target bale channel
flap pressure.
In automatic mode:
• If the alarm is actuated
frequently, reduce the target
force of pressure.
– The pick-up or the cutting unit is
not rotating.
– There is a blockage.
• Check the mechanical system.
• Remove the blockage.
– The knotter motor has not
actuated a knot.
– The "Knotter" sensor has been
incorrectly set.
• Check the electrical system of
the knotter motor.
• Check the mechanism in the
area of the knotter triggering.
• Correctly set the sensor.