EasyManua.ls Logo

Lenze 8400 - Page 337

Lenze 8400
1590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 337
6 I/O terminals
6.1 Digital input terminals
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Inputs
Outputs
Designator
DIS code | data type
Information/possible settings
Counting input DI1 Using DI1(6) as counting input
bCountIn1_ResetCompare
BOOL
Reset status signal "Comparison value reached"
FALSETRUE The output bCountIn1_Compare is reset to FALSE.
bCountIn1_LoadStartValue
BOOL
Load starting value into counter
FALSETRUE The starting value set in C02840/1
is accepted as the current count
value.
Frequency input DI1/DI2 Output of the encoder position of the DI1/DI2 frequency input
bPosIn12_Load
BOOL
(from version 06.00.00)
Load angle integrator with starting value and reset status signal
TRUE Angle integrator is loaded with the value at dnPosIn12_Set_p and
bPosIn12_State is reset to FALSE.
dnPosIn12_Set_p
DINT
(from version 06.00.00)
Starting value for angle integrator
Counting input DI6 Using DI1(6) as counting input
bCountIn6_ResetCompare
BOOL
Reset status signal "Comparison value reached"
FALSETRUE The output bCountIn6_Compare is reset to FALSE.
bCountIn6_LoadStartValue
BOOL
Load starting value into counter
FALSETRUE The starting value set in C02840/3
is accepted as the current count
value.
Designator
DIS code | data type
Value/meaning
bCInh
C00443/2 | BOOL
RFR digital input (controller enable)
Digital inputs DI1 ... DI7 Using DI1(6) and DI2(7) as digital inputs
bIn1 ... bIn7
C00443/2 | BOOL
Digital input DI1 ... DI7
Counting input DI1 Using DI1(6) as counting input
bCountIn1_Compare
BOOL
Status signal "Comparison value reached"
FALSE Current count value < comparison value (C02840/2
)
TRUE Current count value comparison value (C02840/2
)
wCountIn1_HW
wCountIn1_LW
C02841/1 | WORD
Current count value
Output as High and Low word (without sign)
Possible counting range: 0 ... 2
31
-1
Frequency input DI1/DI2 Using DI1(6) and DI2(7) as frequency inputs
nFreqIn12_a
C00446/1 | INT
Output frequency as scaled analog signal in [%]
nFreqIn12_v
C00445/1 | INT
Output frequency as speed signal in [inc/ms]
dnPosIn12_p
DINT
(from version 06.00.00)
Angle output signal
65536 [incr.] 1 encoder revolution
Overflow is possible (display via bPosIn12_State)
bPosIn12_State
BOOL
(from version 06.00.00)
Status signal "Overflow occurred/distance processed"
Status signal can be reset via bPosIn12_Load.
TRUE Overflow has occurred or distance is processed.