Equipment --- Section 5
The Executive 2005
219
• Confirm the house batteries are fully charged.
• The park brake must be applied.
Ensure all people, pets and objects are clear of the Slide-out room path.
• Press and hold the switch in the IN position. The Slide-out room will move slowly in. The
motor will change tone when the Slide-out room is fully retracted.
• Release the switch.
NOTE:
Be sure you have sufficient clearance on the inside of the motorhome (driver seat, etc.)
before you retract the Slide-out room. If the motorhome has a ceramic tile floor
ensure the floor is clean before you retract the Slide-out room. Trapped dirt or grit
under the Slide-out room can scratch the floor surface. Never move the motorhome
with the Slide-out room extended.
CAUTION:
Rain water can pool on the Slide-out awning. The added weight will cause the awning
to sag. Upon retracting the room, material can become caught in between the top of
slide room and the opening in the motorhome. It will be necessary to retract the room
in small increments allowing the water time to run off.
Manual Override Hydraulic - Emergency Procedures:
If the Slide-out room does not operate it is possible a safety feature may be engaged to prevent
room operation.
Check these items if the Slide-out room does not respond from the
switch:
• Is the ignition key OFF?
• Is the park brake applied?
Are all bay doors under the Slide-out room shut, bay door indicator lamp off at Slide-out
switch?
Slide-out room does not respond and the hydraulic pump does not
operate after checking all safety requirements:
• One of the bay doors below the Slide-out may have a faulty electrical
connection at a safety switch (grounded) or one of the safety switches is
out of adjustment.
• Ensure all electrical connections at the switch are good.
All safety switches must be pushed in by the bay door when it closes.
Pump motor operates but the room does not move:
• Check the two fuses adjacent to the hydraulic pump. If the fuses test
good and the room does not operate, it is possible to manually retract a
single galley slide. Dual galley Slide-outs use different hydraulic com-
ponents. Several people (as many as eight) are needed to push in the
room.
• It may be necessary to contact a repair facility to have the problem
diagnosed.
060233
Bay Door Safety Switch

Table of Contents