A total of 16 bits are dened as below:
Bit Meaning Bit Meaning
Bit0 Door 2 selection Bit8 Motor overheat
Bit1 UPS input Bit9 Door 1 safety edge
Bit2 Door open button Bit10 Door 2 safety edge
Bit3 Door close button Bit11 Earthquake signal
Bit4 Safety circuit Bit12 Back door forbidden
Bit5 Door lock circuit 1 Bit13 Half-load signal
Bit6 Door lock circuit 2 Bit14 Single/Double door selection
Bit7 Half-load signal Bit15 Fire emergency oor switchover
14. Output terminal 1 state: indicates the meaning of output terminals by bit. "1" indicates
that the signal is active.
A total of 16 bits are dened as below:
Bit Meaning Bit Meaning
Bit0 Reserved Bit8 Door 2 open
Bit1 RUN contactor Bit9 Door 2 close
Bit2 Brake contactor Bit10 Low 7-segment a display output
Bit3 Higher-voltage startup of brake Bit11 Low 7-segment b display output
Bit4 Fan/Lamp output Bit12 Low 7-segment c display output
Bit5
Shorting PMSM stator contactor
output
Bit13 Low 7-segment d display output
Bit6 Door 1 open Bit14 Low 7-segment e display output
Bit7 Door 1 close Bit15 Low 7-segment f display output
15. Output terminal 2 state: indicates the meaning of CTB outputs by bit. "1" indicates that
the signal is active.
A total of 16 bits are dened as below:
Bit Meaning Bit Meaning
Bit0 Low 7-segment g display output Bit8 Full-load output
Bit1 Up arrow display output Bit9 Inspection output
Bit2 Down arrow output Bit10 Fan/Lamp output 2
Bit3 Minus sign display output Bit11
Shorting door lock circuit contactor
output
Bit4
Returning to base oor at re
emergency output
Bit12
BCD/Gray code/7-segment c ode
high-bit output
Bit5 Buzzer output Bit13
Controller normal running output
active