Troubleshooting NICE1000
new
User Manual
- 190 -
Fault
Code
Name Possible Causes Solution Level
Err58
Shaft position
switches
abnormal
101: The up slow-
down and down slow-
down are disconnected
simultaneously.
102: The up limit feedback
and down limit feedback
are disconnected
simultaneously.
101, 102:
Check whether the states
(NO, NC) of the slow-down
switches and limit switches are
consistent with the parameter
setting of the MCB.
Check whether malfunction of
the slow-down switches and
limit switches occurs.
4B
Err62
Analog input
cable broken
The analog input cable
of the CTB or the MCB is
broken.
Check whether F8-08 is set
correctly.
Check whether the analog
input cable of the CTB or MCB
is connected incorrectly or
broken.
1A
Note
Fault Err41 is not recorded in the elevator stop state.
Fault Err42 is reset automatically when the door lock circuit is shorted or 1s after the fault
occurs in the door zone.
If faults Err51 and Err52 persist, they are recorded once every one hour.
Except the fault code and level, the number (such as 1, 101) indicates the fault subcode.