- 6 -
Landing at another
oor
If the door open time exceeds the door open protection
time but the door open limit signal is still inactive, the
elevator closes the door and then automatically runs to
the next landing oor. The system reports fault Err55.
-
Forced door close
When the door fails to close within the set time due
to the action of the light curtain or safety edge, the
elevator enters the forced door close state, closes the
door slowly, and gives a prompt tone.
-
Service oor setting
You can enable or disable the system service for
certain oors exibly based on actual requirements.
Set in F6-05
Independent
running
The elevator does not respond to any call, and the
door needs to be closed manually. In the case of group
control, the elevator runs independently out of the
group control system.
Enabled when
Bit9 of FE-13 is 1
and independent
running input of
the MCB is active
Attendant running
In attendant state, the running of the elevator is
controlled by the attendant.
-
Low-speed self-
rescue
When the elevator is in non-inspection state and
stops at non-leveling area, the elevator automatically
runs to the leveling area at low speed if the safety
requirements are met, and then opens the door.
-
Door control
function
You can set whether the system keeps outputting
commands after door open limit and door close limit
based on the type of the door machine.
-
Car arrival gong
After the elevator arrives at the destination oor, the
CTB gives a prompt tone.
-
Automatic
startup torque
compensation
The system automatically implements startup torque
compensation based on the current car load, achieving
smooth startup and improving the riding comfort.
Set in F8-01
Direct travel ride
The system automatically calculates and generates
the running curves based on the distance, enabling the
elevator to directly stop at the leveling position without
creeping.
-
Automatic
generation of
optimum curve
The system automatically calculates the optimum
speed curve compliant with the human-machine
function principle based on the distance, without being
limited by the number of curves or short oor.
-
Service suspension
output
When the elevator cannot respond to hall calls, the
corresponding terminal outputs the service suspension
signal.
-
Running times
recording
In automatic running state, the system automatically
records the running times of the elevator.
Recorded in F9-
05 and F9-06
Running time
recording
The system automatically records the accumulative
power-on time, working hours, and working days of the
elevator.
Recorded in
F9-03