- 86 -
Function
Code
Parameter Name Setting Range Default Unit
Property
F4-30
High byte of oor
height 13
0–65535 0 Pulses
★
F4-31
Low byte of oor height
13
0–65535 0 Pulses
★
F4-32
High byte of oor
height 14
0–65535 0 Pulses
★
F4-33
Low byte of oor height
14
0–65535 0 Pulses
★
F4-34
High byte of oor
height 15
0–65535 0 Pulses
★
F4-35
Low byte of oor height
15
0–65535 0 Pulses
★
Group F5: Input Terminal Parameters
F5-00
Attendant/Automatic
switchover time
3–200 3 s
★
F5-01 X1 function selection
1–99: NO input, 101–199: NC
input
00: Invalid
01: Leveling 1 signal
02: Leveling 2 signal
03: Door zone signal
04: RUN contactor feedback
signal
05: Brake travel switch
feedback signal 1
06: Brake travel switch
feedback signal 1
07: Shorting PMSM stator
contactor feedback signal
08: Shorting door lock circuit
contactor feedback
09: Inspection signal
10: Inspection up signal
11: Inspection down signal
12: First re emergency
signal
(To be continued)
03 -
★
F5-02 X2 function selection 104 -
★
F5-03 X3 function selection 105 -
★
F5-04 X4 function selection 109 -
★
F5-05 X5 function selection 10 -
★
F5-06 X6 function selection 11 -
★