- 93 -
Function
Code
Parameter Name Setting Range Default Unit
Property
F7-24 Y24 function selection
43: High 7-segment c display
output
44: High 7-segment d display
output
45: High 7-segment e display
output
46: High 7-segment f display
output
47: High 7-segment g display
output
48–99: Reserved
(End)
00 -
★
F7-25 Y25 function selection 00 -
★
F7-26 Y26 function selection 00 -
★
F7-27 Y27 function selection 00 -
★
Group F8: Enhanced Function Parameters
F8-00
Load for load cell auto-
tuning
0–100 0 %
★
F8-01 Pre-torque selection
0: Pre-torque invalid
1: Load cell pre-torque
compensation
2: Automatic pre-torque
compensation
0 -
★
F8-02 Pre-torque offset 0.0–100.0 50.0 %
★
F8-03 Drive gain 0.00–2.00 0.60 -
★
F8-04 Brake gain 0.00–2.00 0.60 -
★
F8-05 Current car load 0–255 0 -
●
F8-06 Car no-load load 0–255 0 -
★
F8-07 Car full-load load 0–255 100 -
★
F8-08
Load cell input
selection
0: MCB digital sampling
1: MCB analog sampling
0 -
☆
F8-09
Emergency evacuation
operation speed at
power failure
0.000 to F3-11 0.050 m/s
★
F8-10
Emergency evacuation
operation mode at
power failure
0: Motor not running
1: UPS
2: 48 V battery power supply
0 -
★
F8-11 Brake apply delay 0.200–1.500 0.200 s
★
F8-12 Fire emergency oor 2 0 to F6-00 0 -
★