EasyManua.ls Logo

Monarch NICE1000 - Page 96

Monarch NICE1000
205 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Code Table NICE1000
new
User Manual
- 94 -
Function
Code
Parameter Name Setting Range Default Unit
Property
F8-13 Anti-nuisance function
Bit0: Disabled
Bit1: Judged by light curtain
Bit 2: Judged by light-load
signal
0 -
Group F9: Time Parameters
F9-00
Idle time before
returning to base oor
1–240
0: Invalid
10 min
F9-01
Time for fan and lamp
to be turned off
1–240
0: Fan and lamp always ON
2 min
F9-02 Motor running time limit
0–45
Invalid if smaller than 3s
45 s
F9-03
Accumulative running
time
0–65535 0 h
F9-04 Reserved - - -
F9-05
High byte of running
times
0–9999
1 indicating actual running
times 10000
0 -
F9-06
Low byte or running
times
0–9999 0 -
Group FA: Keypad Setting Parameters
FA-00 Reserved - - -
FA-01 Display in running state 1–65535 65535 -
FA-02 Display in stop state 1–65535 65535 -
FA-03 Current encoder angle 0.0–359.9 0.0
Degree
(°)
FA-04 Reserved - - -
-
FA-05
Control board software
(ZK)
0–65535 0 -
FA-06
Drive board software
(DSP)
0–65535 0 -
FA-06 Heatsink temperature 0–100 0 °C
FA-08 Controller model - 1000 -
FA-09 Reserved - - -
-
FA-10 Reserved - - -
-
FA-11 Pre-torque current 0.0–200.0 0 %
FA-12 Logic information 0–65535 0 -
FA-13 Curve information 0–65535 0 -
FA-14 Set speed 0.000–4.000 0 m/s

Table of Contents