Function Code Table NICE1000
new
User Manual
- 96 -
Function
Code
Parameter Name Setting Range Default Unit
Property
Fb-02
Service oors of door
machine 1
0–65535
0: Forbid door open
1: Allow door open
65535 -
Fb-03
Holding time of manual
door open
1–60 10 s
Fb-04
Service oors of door
machine 2
0–65535
0: Forbid door open
1: Allow door open
Valid only when there are two
door machines
65535 -
Fb-05
Delay at stop after
re-leveling
0.00–2.00 0 s
Fb-06
Door open protection
time
5–99 10 s
Fb-07
Program control
selection
0–65535
Bit0–Bit4: Reserved
Bit5: Synchronous motor
current detection
Bit6–Bit12: Reserved
Bit13: Higher voltage/Lower
voltage 1.5s detection
0 -
Fb-08
Door close protection
time
5–99 15 s
Fb-09
Door open/close
protection times
0–20
0: Invalid
0 -
Fb-10
Door state of standby
elevator
0: Closing the door as normal
at base oor
1: Waiting with door open at
base oor
2: Waiting with door open at
each oor
0 -
Fb-11
Door open holding time
for hall call
1–1000 5 s
Fb-12
Door open holding time
for car call
1–1000 3 s
Fb-13
Door open holding time
upon open delay valid
10–1000 30 s
Fb-14
Door open holding time
at base oor
1–1000 10 s
Fb-15
Arrival gong output
delay
0–1000 0 ms