EasyManuals Logo

Motion Control Engineering Motion 4000 User Manual

Motion Control Engineering Motion 4000
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #294 background imageLoading...
Page #294 background image
User Interface
4-116 Manual # 42-02-2P24
FCL Brake Unit Utilities Menu
This menu allows you to check CAN controlled brake module function, check commanded and
actual pick voltage/amperage, default module TC-FCL parameters or calibrate a selected mod-
ule TC-FCL for use on the Motion 4000 controller. Navigate to this menu using the N button,
then select it using the S button to access sub-menus. Navigate between sub-menus using the N
button. Review Brake Module on page 2-12 for information about module addressing and func-
tionality.
FCL Diagnostic Menu
The FCL diagnostic menu allows data in particular module registries to be examined to diag-
nose board-level activity. If you are having a problem with a module and you suspect it is a
problem with one of the module circuit boards, contact MCE Technical Support so that a tech-
nician can work with you to determine whether or not the module is faulty. Generically:
• Use S to move to the module number digit, then +/- to set.
• Use S to move to the register address fields, then +/- to set.
• The LCD will display data present in the selected module register.
FCL Power Data Menu
The FCL power data menu allows you to see commanded and actual pick voltage and amperage
for a selected brake module.
• Use +/- to select the module.
• CMD: Commanded voltage
• V: Actual applied voltage
• A: Actual applied amperage.
Default TC-FCL Parameters
This menu allows you to select a specific module, then default its values to factory settings.
• Place car on Machine Room Inspection.
• Use +/- to select the module. Press S to default.
• The module values will be defaulted to factory values.
FCL Adjustment Menu
This menu is used to calibrate a selected module to Motion 4000 requirements.
• Place car on Machine Room Inspection.
• Use +/- to select the module. Press S to calibrate.
• The selected module will be calibrated and progress reported on the display.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motion Control Engineering Motion 4000 and is the answer not in the manual?

Motion Control Engineering Motion 4000 Specifications

General IconGeneral
BrandMotion Control Engineering
ModelMotion 4000
CategoryController
LanguageEnglish

Related product manuals