EasyManuals Logo

Motion Control Engineering Motion 4000 User Manual

Motion Control Engineering Motion 4000
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #297 background imageLoading...
Page #297 background image
F7: Parameters Adjust
4-119
4
Motion 4000
Controller Parameter/Drive Parameter Interaction
There are very important things to consider about the interaction between motion parameters
set on the drive and the setting or collection of motion parameters on the controller.
Drive parameters LF.20 Contract Speed and LF.11 Motor RPM determine the drive’s Esti-
mated Gear Ratio, LF.25. The drive will not drive the motor any faster than determined by
the Gear Ratio set at LF.22. Please refer to “Speed and Acceleration Control” on page 2-30.
Note
MOTION / DISTANCE DIAGNOSTIC displays are provided through the F5 menu. They can
be very helpful in seeing what is actually happening in the hoistway and using that information
to fine tune settings or diagnose fault conditions. Please refer to “MPI Diagnostic Menu” on
page 4-66.