Troubleshooting
5-62 Manual # 42-02-2P24
ICE-COP-2 Car Panel Interface Board
The ICE-COP-2 board, mounted in the car operating panel, converts the discrete closures from
the panel buttons and switches to data on the CAN serial bus and passes it through the MC-LSI
Landing System Interface board on the cartop, up the traveler to the car controller. Additional
ICE-COP-2 boards are used to accommodate rear doors or installations with many floors, COP
buttons, and lamps.
Spare assignable inputs to and outputs from ICE-COP-2 boards are available depending upon
system configuration.
F1 menu, Serial COP Board Type = ICE-COP-2: ICE-COP-2 board assignable inputs show
up in the Spare Inputs menu as COP FX (front panel board) IO1 - IO7; COP Rx (rear panel
board) IO1 - IO7. Spare outputs (Spare Outputs menu) appear as IO-13 - IO-19 (COP FX
and COP RX).
If the job has ICE-COP-2 boards, unused spare inputs to and outputs from these boards must be
set to NOT USED. If controller software is upgraded in the field, it is very important to check
programmable ICE-COP-2 board inputs and outputs and verify unused connections are set to
NOT USED. Please refer to “Spare Inputs Menu Options” on page 4-27.
Caution
Spare inputs and outputs used on the ICE-COP-2 boards must be 24VDC, not to exceed 6 Watts.
Installation Instructions
1. Turn the power off at the main disconnect.
2. Mount the ICE-COP-2 board(s) inside the COP using the supplied hardware and provid-
ing sufficient clearance for the components.
Caution
Do not replace C-RJ11-CAN-15 cables between the ICE-COP-2 and MC-LSI with RJ11 cables pur-
chased locally. These cables MUST be replaced with C-RJ11-CAN-15 supplied by MCE. For a replace-
ment cable, please contact MCE technical support.
3. Refer to the prints for the job to wire the ICE-COP-2 board.
Caution
This system is designed for 24 VDC circuits only! Do not connect 120 VAC or DC to any
terminal on the ICE-COP-2 board. Connect only the 24V power from connector J34
(24V CUSTOMER LOAD SUPPLY) to the load.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motion Control Engineering Motion 4000 and is the answer not in the manual?

Motion Control Engineering Motion 4000 Specifications

General IconGeneral
BrandMotion Control Engineering
ModelMotion 4000
CategoryController
LanguageEnglish

Related product manuals