Finishing Installation
2-55
2
Motion 4000
Bypassing Faults on Inspection
Before installation and adjustment are complete, faults that will be adjusted out later may dis-
rupt operation. To bypass faults on Inspection mode:
1. On the MPU board, place switch F3 in the UP position (all others down).
2. On the HC-CTL board, use a jumper to short the pins of JP1 Fault Bypass.
3. Press N until the display shows Controller System Menu.
4. Press S to enter the menu.
5. Press N until the LCD displays Inspection Mode Fault Bypass OFF.
6. Press S to change bypass state to ON.
7. Set F3 back to the DOWN position.
This setting bypasses controller response to faults during Inspection operation. When bypass is
no longer necessary, be certain to change this setting to OFF.
Finishing Installation
With the car running safely on Inspection operation, you are ready to finish installation. This
section describes installing:
Landing/positioning system
Door operator
•Car operating panel
Fire service peripherals
Hall Calls
You must also:
Balance the car and counterweight
Adjust brake to hold 125% of full load