F7: Parameters Adjust
4-125
4
Motion 4000
192 Speed Drop Delay 800 ms
Magnetek drives only. Time in
milliseconds during which the
drive should continue to exert
motor control after the car has
achieved the floor and before the
brake has dropped.
193 Profile Compensation Fixed
Dynamic: Variable, controller
determined compensation for
drive lag based on entry in
parameter 140, Profile Advance.
Fixed: Fixed compensation for
drive lag using the parameter
140, Profile Advance setting.
194
Normal Brake Pick Volt-
age
0V 300V
195
Normal Brake Hold
Voltage
0V 300V
196
Normal Brake Relevel
Voltage
0V 300V
197 Normal Brake Lift Rate 0% 100%
198
Normal Brake Drop
Rate
0% 100%
199 Emergency Brake Type Module or Discrete
200
Emergency Brake Pick
Voltage
0V 300V
201
Emergency Brake Hold
Voltage
0V 300V
202 Directional Limit Type VIRTUAL VIRTUAL, PHYSICAL
203
Landing System Floor
Checksum
Read only value.
204
Landing System ETS
Overspeed
0% 0% N/A
205 Inspection Slew Filter 0.1 Hz 20.0 Hz 20.0 Hz
206 Battery Backup Speed 9 FPM 250 FPM 250 FPM
Table 4.17 F7 Parameters
# Item Min Default Max Notes