Status and Error Messages
5-37
5
Motion 4000
SPA IS OFFLINE
Description: HC-CTL board safety processor A is offline.
Troubleshooting:
1. HC-CTL board power may not be connected. Check the CAN bus connection between the HC-CTL board
and the HC-CHP CAN board.
2. Make sure jumper JP3 on the HC-CTL board is not shorted.
3. If the SPA indicator is not lighted, reboot the processor by cycling power to the controller or by remov-
ing the CAN bus connection to the HC-CTL board for a few seconds.
4. If fault occurs while updating software, refer to update instructions and repeat process.
SPB IS OFFLINE
Description: HC-CTL board safety processor B is offline.
Troubleshooting:
1. Power to the HC-CTL board may not be connected. Check the CAN bus connection between the HC-CTL
board and the HC-CHP CAN hub and board.
2. Make sure jumper JP4 on the HC-CTL board is not shorted.
3. If the SPB indicator is not lighted, reboot the processor by cycling power to the controller or by remov-
ing the CAN bus connection to the HC-CTL board for a few seconds.
4. If fault occurs while updating software, refer to update instructions and repeat process.
SPC IS OFFLINE
Description: HC-CTL board safety processor C is offline.
Troubleshooting:
1. Power to the HC-CTL board may not be connected. Check the CAN bus connection between the HC-CTL
board and the HC-CHP CAN hub and board.
2. Make sure jumper JP6 on the HC-CTL board is not shorted.
3. If the SPC indicator is not lighted, reboot the processor by cycling power to the controller or by remov-
ing the CAN bus connection to the HC-CTL board for a few seconds.
4. If fault occurs while updating software, refer to update instructions and repeat process.
TIME OUT OF SERVICE
Description: The T.O.S. timer has expired.
Troubleshooting: The elevator has been delayed, usually by a door being obstructed. The Time Out of
Service timer has expired and the elevator has been taken out of service.
TOP ACCESS SW. FAILURE
Description: The Up and Down Top Access switch inputs are active at the same time.
Troubleshooting: Check the wiring and the switch associated with the ATU and ATD inputs.
UP AND DOWN TERMINAL SPEED REDUCING LIMITS OPEN
Description: Floors have not been learned.
Troubleshooting: Check parameters for UNTS1 and DNTS1. Make sure that D/UNTS1 option is set to VIR-
TUAL. If no Elgo tape has been hung, put the car on Inspection Bypass Mode (F3 menu) to stop this fault.
Table 5.1 Status and Error Messages
Scrolling Message - Special Event Message

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motion Control Engineering Motion 4000 and is the answer not in the manual?

Motion Control Engineering Motion 4000 Specifications

General IconGeneral
BrandMotion Control Engineering
ModelMotion 4000
CategoryController
LanguageEnglish

Related product manuals