EasyManua.ls Logo

Newtec MDM6000 - Page 224

Newtec MDM6000
325 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Newtec Proprietary
Confidentiality: Unrestricted
V1.0
214/314
Feature Descriptions MDM6000 Satellite Modem
The following table describes the monitoring table:
Parameter Value Description
Monitoring
Index 1 This is the ID of your demodulator.
State on/off The AUPC client is active or inactive. When active,
reporting is done between the AUPC Client and the
AUPC Controller.
In this case the compensation value is sent back to the
controller.
Input Level dBm Displays the current input level measured on the Rx
interface of the demodulator.
Es/N0 dB Displays the current Es/No value measured on the Rx
interface of the demodulator.
Current
Compensation
dB Displays the compensation factor that is required to
reach the nominal power value. The compensation factor
is reported to the AUPC controller.
Estimated
remote uplink
Fading
dB The fading estimate is derived from the nominal Es/No
and the measured Es/No on the Rx interface of the
demodulator.

Table of Contents

Other manuals for Newtec MDM6000

Related product manuals