Feature Descriptions MDM6000 Satellite Modem
14.10 DC BUC Power On L-Band Tx
The MDM6000 offers an optional DC power supply on the L-band Tx interface that can be used to
power BUCs. This option combines the L-band transmit signal coming from the modulator with a DC
power supply and an optional 10MHz reference signal. All these signals can be combined onto the
L-band Tx Interface (N-connector).
The DC power supply (when enabled) provides a24V or 48V DC voltage with a maximum
continuous current of 3.8A on the L-band Tx interface. Both possibilities are available when one of
the following sales options, OU-05 or OU-06, is ordered.
14.10.1 Back Panel Description
The following figure shows the L-Band Tx connector when the BUC power for L-band Tx option is
ordered.
The connector used is an N-connector 50 Ohm (Female).
Two LEDs indicate the state of the power supply.We refer to section
LEDBehavioroftheDCBUCPowerforL-BandTxonpage220.
Switch off the power of the device before connecting the coax cable. This reduces the
risk of personal injury from electric shock or damage to the device.
The maximum continuous current on this connector is 3.8A.
Use a coax cable (Cable Type DP-2!) as marked on the device.
This cable is tested for a maximum 60V DC and a maximum of 8A.