How to Manage the Device MDM6000 Satellite Modem
11.7.10 Displayed Units
Some variables are by default scaled to a more readable unit.
For example:
• Symbol rate in Mbaud;
• Bit rate in Mbps;
• Frequencies in MHz.
When entering a new value (without specifying a scale) the default unit scaling is
applied.
For example:
[MDM6000] modulator# set outputfrequency=1550
OK
[MDM6000] modulator# outputfrequency get
1550 MHz
11.7.11 Get and Set Parameter Values
Use these commands to read out and set parameter values.
It is not mandatory to navigate to the specific branch to execute a command. It is
possible to request or set a value from the main branch.
From a sub branch it is possible to get/set a value from another sub branch. Do this
by entering a prefix "/" to indicate that the navigation starts from the main branch.
Get
» Type the location and the parameter name to readout the requested parameter value.