Appendix - Alarm List MDM6000 Satellite Modem
15.1 Generic Alarms
Alarm Description
Temperature This alarm is raised when the monitored temperature
exceeds 85 °C.
General Device This alarm can be triggered by one of the following alarms:
Invalid License;
Boot Config Failure;
Temperature
Modulator DAC Failure;
Modulator No Calibration Data;
Modulator Ref synthesizer failure alarm
Modulator LO-1 synthesizer failure alarm
Modulator LO-2 synthesizer failure alarm
General Interface This alarm is raised when an error is reported on an interface
that is used in the data path.
This alarm can be triggered by one of the following alarms:
Ethernet interface alarm.
Ref Clock No Signal;
Demodulator No PL Lock;
Demodulator No Lock;
Demodulator Input Saturated;
Demodulator LNB Power Control Error.
Invalid License This alarm is raised when the license file is not available or
wrongly signed.
Boot Config Failure This alarm is raised when an erroneous boot configuration
was attempted to load and failed.
Check the boot configuration file stored on the device.
Frontpanel Internal Failure This alarm is raised when the front panel communication
failed.
Power Supply Failure This alarm is raised when the power supply (A or B) has
failed.
Fan Failure This is alarm is raised when a fan failure occurs.