Feature Descriptions MDM6000 Satellite Modem
The following table describes the alarm states table:
Parameter
State
Description
Alarm States
Index 1 This is the ID of your demodulator.
AUPC Client
Calibration
Absent
This alarm indicates that the AUPC client subsystem
has not been calibrated.
AUPC Client
Calibration
violation
This alarm indicates that the AUPC client wants to
operate outside the calibrated range.
14.8.5.5 AUPC Logging
The logging files are useful during evaluation of the AUPC feature but they also become important
during debugging.
Logging files of the AUPC can always be viewed or downloaded from the Tasks Pane (Refer to the
following figure).
To be able to perform good logging it is mandatory that the date and the time of all the
devices in the system setup are correctly configured.
The following Log files are available.
Client Log;
AUPC terminals Log;
AUPC level log.