Take note that the following parameters are not displayed in the light load mode:
A054
DC Injection
Braking Power
0 to 100[%] 50[%] 0 to 70[%] 50[%]
A057
Startup DC
Injection Braking
Power
0 to 100[%] 0[%] 0 to 70[%] 0[%]
A059
DC Injection
Braking Carrier
Frequency
2.0 to 15.0 [kHz] 5.0 [kHz] 2.0 to 10.0 [kHz] 2.0 [kHz]
b022/b222
Overload Limit 1/
2 Level
0.20 to 2.00
× Rated current
[A]
1.50 ×
Rated current
[A]
0.10 to 1.50
× Rated current
[A]
1.20 ×
Rated current
[A]
b025
Overload Limit 1
Level 2
b028
Frequency Pull-in
Restart Level
0.20 to 2.00
× Rated current
[A]
Inverter rated
current [A]
0.10 to 1.50
× Rated current
[A]
Inverter rated
current [A]
b083
Carrier
Frequency
2.0 to 15.0 [kHz] 10.0 [kHz] 2.0 to 10.0 [kHz] 2.0 [kHz]
H003/
H203
Motor Capacity
1/2
0.1 to 18.5 [kW]
Capacity
indicated by
the type
0.1 to 18.5 [kW]
Capacity
indicated by
the type
Parameter
No.
Function name
Heavy load (CT) Light load (VT)
Setting range Default value Setting range Default value
Parameter
No.
Function name
Parameter
No.
Function name
d009 Torque Reference Monitor H005/H205 Speed Response 1/2
d010 Torque Bias Monitor H020/H220 Motor 1/2 Parameter R1
d012 Output Torque Monitor H021/H221 Motor 1/2 Parameter R2
b040 Torque Limit Selection H022/H222 Motor 1/2 Parameter L
b041
Torque Limit 1
(Four-quadrant Mode Forward
Power Running)
H023/H223 Motor 1/2 Parameter Io
b042
Torque Limit 2
(Four-quadrant Mode Reversed
Regeneration)
H024/H224 Motor 1/2 Parameter J
b043
Torque Limit 3
(Four-quadrant Mode Reversed
Power Running)
H030/H230
Motor 1/2 Parameter R1
(Auto-tuning Data)
b044
Torque Limit 4
(Four-quadrant Mode Forward
Regeneration)
H031/H231
Motor 1/2 Parameter R2
(Auto-tuning Data)
b045 Torque LADSTOP Selection H032/H232
Motor 1/2 Parameter L
(Auto-tuning Data)
b046
Reverse Rotation Prevention
Selection
H033/H233
Motor 1/2 Parameter Io
(Auto-tuning Data)
C054 Overtorque/Undertorque Selection H034/H234
Motor 1/2 Parameter J
(Auto-tuning Data)
C055
Overtorque Level
(Forward Power Running)
P033 Torque Reference Input Selection

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE MX2 SERIES and is the answer not in the manual?

Omron SYSDRIVE MX2 SERIES Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE MX2 SERIES
CategoryInverter
LanguageEnglish

Related product manuals