5-91
5-7 Digital Operator/Operation Functions
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
5
Functions
Display Fixed (DISP)
When "86: DISP" is allocated to a multi-function input terminal and the terminal is turned ON,
the Digital Operator switches to the display selected by Initial Screen Selection (b038) and
other parameters can no longer be displayed.
Password Function
A password can be set for Display Selection (b037) and Soft Lock Selection (b031) to prevent
displaying and changing of parameters.
 If you forget the set password, no other method is available to cancel the password lock. Exercise
due caution when setting a password, because our factory or service station cannot check the
password.
Note 1: 0000 cannot be set as a password.
Note 2: Sixteen characters including 0 to 9, A, b, C, d, E and F (hexadecimals) can be used to set a
password.
Parameter
No.
Function name Data
Default
setting
Unit
C001 to C007
Multi-function
Input Selection
86: DISP (Display fixed)
−−
Related functions b038
Parameter
No.
Function
name
Data Description
Default
setting
Unit
b190
Password A
Setting
0000 Password function disabled
0000 −
0001 to FFFF
Set password A for Display Selection
(b037).
b191
Password A
Authentication
0000 to FFFF
This parameter is used to authenticate
password A.
0000 −
b192
Password B
Setting
0000 Password function disabled
0000 −
0001 to FFFF
Set password B for Soft Lock Selection
(b031).
b193
Password B
Authentication
0000 to FFFF
This parameter is used to authenticate
password B.
0000 −
Related functions b031, b037