5-87
5-7 Digital Operator/Operation Functions
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
   5
Functions
Initial Screen Automatic Switching Function
This function is enabled when Initial Screen Automatic Switching Function is set to "01: Enabled." 
If the Digital Operator is not operated for 10 minutes, the display automatically switches to the
initial screen set by b038. 
Main Panel Display Selection
Once the Remote Operator is connected, the keys on the main unit become disabled. Set the
parameter number to be displayed on the main display at this time. 
Parameter 
No.
Function name Data
Default 
setting
Unit
b164
Initial Screen 
Automatic 
Switching Function
00: Disabled (Not switching 
automatically)
00 −
01: Enabled (Switching automatically)
Parameter 
No.
Function name Data
Default 
setting
Unit
b150
Main Panel 
Display Selection
001 to 060
Corresponding to d001 to d060 in the 
monitor mode. 
001