4-6
4-2 Function Mode
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
4
Parameter List
Parameter
No.
Function name Monitor or data range
Default
setting
Set data
Data can
be set
during
RUN
Data can be
changed
during RUN
Unit
Page
Multi-step speed/jogging
A019
Multi-step
Speed
Selection
00: Binary (16-step selection
with 4 terminals)
01: Bit (8-step selection with 7
terminals)
00 no no −
5-63
A020
Multi-step
Speed 1
Reference 0
0.00
Starting frequency to
Maximum Frequency 1
6.00 yes yes Hz
A220
Multi-step
Speed 2
Reference 0
0.00
Starting frequency to
Maximum Frequency 2
6.00 yes yes Hz
A021
Multi-step
Speed
Reference 1
0.00
Starting frequency to
Maximum Frequency
0.00
yes yes Hz
A022
Multi-step
Speed
Reference 2
0.00
A023
Multi-step
Speed
Reference 3
0.00
A024
Multi-step
Speed
Reference 4
0.00
A025
Multi-step
Speed
Reference 5
0.00
A026
Multi-step
Speed
Reference 6
0.00
A027
Multi-step
Speed
Reference 7
0.00
A028
Multi-step
Speed
Reference 8
0.00
A029
Multi-step
Speed
Reference 9
0.00
A030
Multi-step
Speed
Reference 10
0.00
A031
Multi-step
Speed
Reference11
0.00
A032
Multi-step
Speed
Reference 12
0.00
A033
Multi-step
Speed
Reference 13
0.00

Table of Contents