Loading...
9-19
9-3 Options
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
9
Specifications
Operating environment
Radio Noise Filter
Dimensional Drawing
3G3AX-ZCL1
3G3AZ-ZCL2
Ambient
temperature
10 to 50°C
Humidity 20% to 90% RH (with no condensation)
Vibration
15 kW max. 5.9 m/s
2
max. (0.6 G) 10 to 55 Hz
22 kW min. 2.0 m/s
2
max. (0.2 G) 10 to 55 Hz
Location
At a maximum altitude of 1,000 m; indoors (without
corrosive gases or dust)
160
18
129
85
180
(23)
10
14
7 x 14 long and round mounting hole
7 dia. mounting hole
7
83
35
32
3
3-M4
26
max.
95 max.
2-φ5.5
80 ± 0.5
78 max.
12.5 ± 0.3
φ39.5 mm
7
72 ± 0.5