5-111
5-9 Functions Relating to Protections, Warnings and Various Output Signals
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
5
Functions
Reduced Torque Characteristics
Multiplied by the time limit characteristics set in b012/212 for each frequency.
Example) 3G3MX2-**, base frequency 60 Hz, light load setting (rating 9.6 A = b012)
Constant Torque Characteristics
Do not skip this setting when using a constant torque motor.
Example) 3G3MX2-**, base frequency 60 Hz, heavy load setting (rating 8.0 A = b012)
Reduction
multiple
Base frequency
Inverter output frequency (Hz)
×
1.0
×
0.8
×
0.6
0
0
5
6
16
20
50
60
60 Hz (reduction multiple:
×
1.0) 20 Hz (reduction multiple:
×
0.8)
A
larm
time (s)
Motor
current (A)
Alarm
time (s)
Motor
current (A)
60
0.5
0
11.1 11.5 14.4
[A]
(116%)(120%)
(150%)
60
3.0
0
8.9 9.2 11.5
[A]
(92.8%)(96%)
(120%)
Reduction
multiple
Inverter output
frequency (Hz)
×
1.0
×
0.8
0
3
60
60 Hz (reduction multiple:
×
1.0)
Less than 3 Hz (reduction multiple:
×
0.8)
A
larm
time (s)
Motor current (A)
Alarm
time (s)
60
3.0
0
8.72 12 16
[A]
(109%)(150%)
(200%)
60
3.0
0
7.0 9.6 12.8
[A]
(87.2%)(120%)
(160%)
Motor current (A)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE MX2 SERIES and is the answer not in the manual?

Omron SYSDRIVE MX2 SERIES Specifications

General IconGeneral
BrandOmron
ModelSYSDRIVE MX2 SERIES
CategoryInverter
LanguageEnglish

Related product manuals