5-176
5-14 Other Functions
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
   5
Functions
Major Differences between High-frequency Mode and Normal Mode 
Note: In the high-frequency mode, the values are fixed and thus parameters b049, A097, A098 and b089
are not displayed. 
Function name
High-frequency 
mode
Normal mode 
Heavy Load/Light Load 
Selection (b049) 
Heavy load rating (CT) Heavy load rating (CT) Light load rating (VT)
Maximum Frequency 
(A004)
1000 [Hz]
400 [Hz]
400 [Hz]
Starting Frequency 
(b082) 
0.10 to 100.0 [Hz]
0.10 to 9.99 [Hz]
0.10 to 9.99 [Hz]
Carrier Frequency 
(b083)
2.0 to 10.0 [kHz]
2.0 to 15.0 [kHz]
2.0 to 10.0[kHz]
Control Method (A044)
00: Constant torque 
characteristics
01: Reduced torque 
characteristics
02: Free V/f setting
00: Constant torque 
characteristics
01: Reduced torque 
characteristics
02: Free V/f setting
03: Sensorless vector 
control 
00: Constant torque 
characteristics
01: Reduced torque 
characteristics
02: Free V/f setting
Acceleration Pattern 
Selection (A097)
Deceleration Pattern 
Selection (A098)
00: Line
00: Linear
01: S shape curve
02: U shape curve
03: Reverse-U shape 
curve
04: EL-S shape curve
00: Linear
01: S shape curve
02: U shape curve
03: Inverted U shape 
curve
04: EL-S shape curve
Automatic Carrier 
Reduction (b089)
Disable Setting permitted Setting permitted
Heavy load mode
b049 :  00
d060 :  1-c
Light load mode
b049 : 01
d060 : 1-
High-frequency mode
d060 :  h-1
Normal mode (to 400 Hz)
Heavy load rating
High-frequency mode (to 1,000 Hz)
b171  = 01
+ 
Initialization
b049  = 01
b049  = 00
b171  = 02
+ 
Initialization
b171  = 02
+ 
Initialization 
Light load rating