EasyManua.ls Logo

Omron SYSDRIVE MX2 SERIES - Page 291

Omron SYSDRIVE MX2 SERIES
446 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-176
5-14 Other Functions
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
5
Functions
Major Differences between High-frequency Mode and Normal Mode
Note: In the high-frequency mode, the values are fixed and thus parameters b049, A097, A098 and b089
are not displayed.
Function name
High-frequency
mode
Normal mode
Heavy Load/Light Load
Selection (b049)
Heavy load rating (CT) Heavy load rating (CT) Light load rating (VT)
Maximum Frequency
(A004)
1000 [Hz]
400 [Hz]
400 [Hz]
Starting Frequency
(b082)
0.10 to 100.0 [Hz]
0.10 to 9.99 [Hz]
0.10 to 9.99 [Hz]
Carrier Frequency
(b083)
2.0 to 10.0 [kHz]
2.0 to 15.0 [kHz]
2.0 to 10.0[kHz]
Control Method (A044)
00: Constant torque
characteristics
01: Reduced torque
characteristics
02: Free V/f setting
00: Constant torque
characteristics
01: Reduced torque
characteristics
02: Free V/f setting
03: Sensorless vector
control
00: Constant torque
characteristics
01: Reduced torque
characteristics
02: Free V/f setting
Acceleration Pattern
Selection (A097)
Deceleration Pattern
Selection (A098)
00: Line
00: Linear
01: S shape curve
02: U shape curve
03: Reverse-U shape
curve
04: EL-S shape curve
00: Linear
01: S shape curve
02: U shape curve
03: Inverted U shape
curve
04: EL-S shape curve
Automatic Carrier
Reduction (b089)
Disable Setting permitted Setting permitted
Heavy load mode
b049 : 00
d060 : 1-c
Light load mode
b049 : 01
d060 : 1-
High-frequency mode
d060 : h-1
Normal mode (to 400 Hz)
Heavy load rating
High-frequency mode (to 1,000 Hz)
b171 = 01
+
Initialization
b049 = 01
b049 = 00
b171 = 02
+
Initialization
b171 = 02
+
Initialization
Light load rating

Table of Contents

Related product manuals