6-68
6-8 List of Modbus Communication (Modbus-RTU) Data
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-Axxxx)
6
Communication Function
1699h
Recipient Register of All
Stations in Co-inverter
Communication 4
P151 R/W 0000h to FFFFh −
6-22
169Ah
Sender Register of All
Stations in Co-inverter
Communication 4
P152 R/W 0000h to FFFFh −
169Bh
Recipient Station
Number of All Stations in
Co-inverter
Communication 5
P153 R/W 1 to 247 −
169Ch
Recipient Register of All
Stations in Co-inverter
Communication 5
P154 R/W 0000h to FFFFh −
169Dh
Sender Register of All
Stations in Co-inverter
Communication 5
P155 R/W 0000h to FFFFh −
169Eh
to
16BCh
Reserved −−− − −
16BDh
to
1E00h
Not used −−Inaccessible −−
1E01h Coil Data 1
*1
− R
2
0
: Coil number 0010h to
2
15
: Coil number 001Fh
−−
1E02h Coil Data 2
*1
− R
2
0
: Coil number 0020h to
2
15
: Coil number 002Fh
−−
1E03h Coil Data 3
*1
− R
2
0
: Coil number 0030h to
2
15
: Coil number 003Fh
−−
1E04h Coil Data 4
*1
− R
2
0
: Coil number 0040h to
2
15
: Coil number 004Fh
−−
1E05h Coil Data 5
*1
− R
2
0
: Coil number 0050h to
2
8
: Coil number 0058h
−−
1E06h
to
1E18h
Reserved −−− − −
1E19h
to
1F00h
Not used −−Inaccessible −−
1F01h Coil Data 0
*1
− R/W
2
1
: Coil number 0001h to
2
15
: Coil number 000Fh
−−
1F02h
to
1F1Dh
Reserved −−−
*2
−−
1F1Eh
to
2102h
Not used −−Inaccessible −−
*1. Each of the above holding registers (coil data 0 to 5) consists of 16 coil data. Since coils are not
supported in Co-inverter communication (only holding registers are supported), use the above holding
registers when accessing coils.
*2. Do not write into holding registers 1F02h to 1F1Dh.
Register
No.
Function name
Parameter
No.
R/W
Monitor and setting
parameters
Data
resolution
Page