Monitoring System Components
Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)
/SYS/DBP FRU Disk backplane FRU
/SYS/DBP/PRSNT Discrete sensor Disk backplane presence 01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/DBP/HDD[0-x] Pseudo Hard disk drives (HDD)
/SYS/DBP/HDD[0-x]/PRSNT Discrete sensor Hard disk drive presence 01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
/SYS/DBP/HDD[0-x]/STATE State sensor Hard disk drive state 01h-FAULT_STATUS
02h-IDENTITY
04h-INSTALLED
20h-SLOT_POWER_OFF
/SYS/DBP/HDD[0-x]/SERVICE Indicator Fault-Service Required
LED
Color: Amber
Location: HDD
Off: Normal
On: HDD was diagnosed as faulty
/SYS/DBP/HDD[0-x]/OK2RM Indicator Hard disk drive OK to
remove
Color: Blue
Location: HDD
Off: Normal
On: HDD is OK to remove
/SYS/DBP/HDD[0-x]/NVME FRU NVMe drive FRU
/SYS/DBP/HDD[0-x]/NVME/PRSNT Discrete sensor NVMe device presence 01h-ENTITY_ABSENT
02h-ENTITY_PRESENT
Related Information
■
“System Chassis Components” on page 285
■
“Cooling Unit Components” on page 287
■
“Memory Device Components” on page 289
■
“Power Unit Components” on page 289
■
“Processor Components” on page 290
■
“System Motherboard Components” on page 291
■
“System Firmware Components” on page 293
■
“Hard Disk Drive Components” on page 293
288 Oracle Server X7-2 Service Manual • October 2017