Monitoring System Components
■
“Hard Disk Drive Components” on page 293
System Chassis Components
The following table lists the system chassis components.
Component Name (Oracle
ILOM CLI Targets)
IPMI Type Description Values (if applicable)
/SYS FRU Product information only
/SYS/UUID FRU Unique system ID Derived from host MAC address. Used for
PXE boot and licensing.
/SYS/ACPI State sensor Advanced Configuration and Power
Interface
(hidden)
01h-ACPI_ON_WORKING
20h-ACPI_SOFT_OFF
/SYS/VPS Threshold
sensor
Virtual power sensor Watts
/SYS/VPS_CPUS Threshold
sensor
Virtual power sensor (CPUs) Watts
/SYS/VPS_MEMORY Threshold
sensor
Virtual power sensor (Memory) Watts
/SYS/VPS_FANS Threshold
sensor
Virtual power sensor (Fans) Watts
/SYS/T_AMB Threshold
sensor
Ambient temperature on system
motherboard
Degrees Celsius
/SYS/TEMP_FAULT Indicator Temperature Fault LED Color: Amber
Location: Front panel
Off: Normal
On: Chassis overtemp fault
/SYS/OK Indicator System OK LED Color: Green
Location: Front and back panels
Off: Power is off.
Standby blink: Standby power is on; Oracle
ILOM SP is running.
Slow blink: Startup sequence initiated on
host.
On: Host is booting OS or running the OS.
Monitoring Components and Identifying SNMP Messages 285