EasyManuals Logo

Oracle X7-2 Service Manual

Oracle X7-2
312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #300 background imageLoading...
Page #300 background image
Power Events
Messages and Descriptions Component Name
SNMP Trap: sunHwTrapSensorCritThresholdExceeded
Oracle ILOM Event Message: Lower critical threshold exceeded
Severity and Description: Major; A power supply sensor has reported that its value has gone
above an upper critical threshold setting or below a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
SNMP Trap: sunHwTrapSensorCritThresholdDeasserted
Oracle ILOM Event Message: Lower critical threshold no longer exceeded
Severity and Description: Informational; A power supply sensor has reported that its value has
gone below an upper critical threshold setting or above a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/P_IN
/SYS/PS[0-1]/P_OUT
SNMP Trap: sunHwTrapVoltageFatalThresholdExceeded
Oracle ILOM Event Message: Lower fatal threshold exceeded
Severity and Description: Critical; A voltage sensor has reported that its value has gone above
an upper fatal threshold setting or below a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
SNMP Trap: sunHwTrapVoltageFatalThresholdDeasserted
Oracle ILOM Event Message: Lower fatal threshold no longer exceeded
Severity and Description: Informational; A voltage sensor has reported that its value has gone
below an upper fatal threshold setting or above a lower fatal threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
SNMP Trap: sunHwTrapVoltageCritThresholdExceeded
Oracle ILOM Event Message: Upper critical threshold exceeded
Severity and Description: Critical; A voltage sensor has reported that its value has gone above
an upper critical threshold setting or below a lower critical threshold setting.
The sunHwTrapThresholdType object indicates whether the threshold was an upper or lower
threshold.
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
SNMP Trap: sunHwTrapVoltageCritThresholdDeasserted
Oracle ILOM Event Message: Upper critical threshold no longer exceeded
Severity and Description: Informational; A voltage sensor has reported that its value has gone
below an upper critical threshold setting or above a lower critical threshold setting.
/SYS/PS[0-1]/V_12V
/SYS/PS[0-1]/V_12V_STBY
/SYS/PS[0-1]/V_IN
300 Oracle Server X7-2 Service Manual • October 2017

Table of Contents

Other manuals for Oracle X7-2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle X7-2 and is the answer not in the manual?

Oracle X7-2 Specifications

General IconGeneral
ProcessorIntel Xeon Scalable processors
Number of Processors1 or 2
MemoryUp to 1.5 TB DDR4
Memory Slots24 DIMM slots
Form Factor2U Rackmount
Storage Bays8 x 2.5-inch
CPU SocketSocket P (LGA 3647)
Power SupplyRedundant hot-swappable power supplies