SERVICE CALL CODE TABLE
C262/C265 4-8 SM
Code Title Conditions Possible Causes
SC725
Paper table motor
lock – LCOT
The paper table upper limit sensor
or lower limit sensor does not
change the status for more than 15
seconds after the paper table motor
on signal is generated.
Defective sensor
Defective motor
Mechanism blocked by
foreign material
ACU
SC818
Watch-dog error While the system program is running,
other processes do not operate at all.
Defective ACU board
Software error (ACU)
SC819
Kernel panic error Processing cannot be continued by
kernel
Software error (ACU)
SC820
Self-Diagnostic
Error: CPU
The central processing unit returned
an error during the self-diagnostic
test.
ACU board defective
Software defective (ACU)
SC821
Self-Diagnostic
Error: ASIC
The ASIC returned an error during
the self-diagnostic test because the
ASIC and CPU timer interrupts were
compared and determined to be out
of range.
ACU board defective
SC822
Self-Diagnostic
Error: HDD
The hard disk drive returned an error
during the self-diagnostic test.
HDD defective
HDD connector defective
ACU board defective
SC823
Self-diagnostic
Error: NIC
The network interface control
returned an error during the self-
diagnostic test.
Defective ACU board
SC824
Self-diagnostic
Error: NVRAM
The resident non-volatile RAM
returned an error during the self-
diagnostic test.
NVRAM of ACU board
damaged or abnormal
ACU board defective
NVRAM socket damaged
SC826
Self-diagnostic
Error: NVRAM
The NVRAM returned an error during
the self-diagnostic test.
NVRAM of ACU board
defective
SC827
Self-diagnostic
Error: RAM
The resident RAM returned a verify
error during the self-diagnostic test.
Defective ACU board
SC828
Self-diagnostic
Error: ROM
The resident read-only memory
returned an error during the self-
diagnostic test.
ACU board defective
Firmware defective
(ACU)
SC829
Self-diagnostic
Error: DIMM-RAM
The DIMM-RAM returned an error
during the self-diagnostic test.
DIMM-RAM defective
ACU board defective
SC835
Self-Diagnostic
Error: Centro
device
Loopback test error.
Loopback connector not
detected
IEEE1284 connector
defective
ACU board defective
SC836
Self-diagnostic
Error: Resident
Font ROM
The resident font ROM returned an
error during the self-diagnostic test.
Defective ACU board
SC837
Self-diagnostic
Error: Optional
Font ROM
The optional font ROM returned an
error during the self-diagnostic test.
Defective ACU board
SC838
Self-diagnostic
Error: Clock
generator
The setting value of the clock
generator is wrong
Defective ACU board